(jointly with Renewable Energy Agency (REA))
Objection: Quantitive assessment of biogas collection at MSW landfills
Activities: Short-term and long term pump tests
Short-term pump test at MSW landfill of Chernivtsi city
Place of implementation: MSW landfill of Chernivtsi city, Ukraine
Execution period: 07/2007
Main parameters of test LFG collection system
Number of wells: | 3 |
Average LFG flow rate: | 40 m3/h |
Average CH4 content in LFG: | 40,0% |
Utilization of LFG: Combustion in a flaring stack
Main results of modelling
Average LFG flow rate for the period 2010 2012: | 600-750 m3/h |
GHG emission reductions into the atmosphere for 2010-2012: | 50 th. t СО2-eq/yr |
Long-term pump test at MSW landfill of Mariupol city
Place of implementation: MSW landfill of Mariupol city, Ukraine
Execution period: 08-09/2008
Main parameters of test LFG collection system
Number of wells: | 3 |
Average LFG flow rate: | 30 m3/h |
Average CH4 content in LFG: | 43,0% |
Utilization of LFG: Combustion in a flaring stack
Main results of modelling
Average LFG flow rate for the period 2010 2012: | 400-600 m3/h |
GHG emission reductions into the atmosphere for 2010-2012: | 30,0 th. t СО2-eq/yr |